L3-26: DC Bus Capacitors Extension
No.
Name
(Hex.)
L3-26
DC Bus Capacitors
Extension
(0455)
Expert
L3-27: StallP Detect Time
No.
Name
(Hex.)
L3-27
StallP Detect Time
(0456)
L3-34: Torque Lim.Delay Time
No.
Name
(Hex.)
L3-34
Torque Lim.Delay Time
(016F)
Expert
When vibration occurs during operation of Single Drive KEB Ride-Thru 2, increase this parameter in 0.010-unit
increments.
Note:
The Single Drive KEB Ride-Thru 2 mode operates when L2-29 = 2 [KEB Method = Single KEB2 Ride-Thru] and H1-xx = 42 or 43
[Terminal DIx Function Select = KEB Thru2 NC or KEB Thru2 NO].
L3-35: SpAgree Width@StallP
No.
Name
(Hex.)
L3-35
SpAgree Width@StallP
(0747)
Expert
Set this parameter when hunting occurs while you use a frequency reference through an analog input.
L3-36: VibSup Gain@Accel
No.
Name
(Hex.)
L3-36
VibSup Gain@Accel
(11D0)
If there is vibration in the output current during acceleration, increase the setting value.
Note:
Set L3-01 = 4 [StallP Mode@Accel = ILim Mode] to enable this function.
L3-37: CurLim ITime@Accel
No.
Name
(Hex.)
L3-37
CurLim ITime@Accel
(11D1)
Expert
Note:
Set L3-01 = 4 [StallP Mode@Accel = ILim Mode] to enable this function.
SIEPCYEUOQ2V01A Q2V Technical Manual
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the capacity for external main circuit capacitors. Usually it is not necessary to change this
setting. Sets this parameter when you use the KEB Ride-Thru function.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets a delay time between reaching the Stall Prevention level and starting the Stall Prevention
function.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the filter time constant that returns the torque limit to its initial value when KEB operation
operates in Single Drive KEB Ride-Thru mode.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the width for speed agreement when L3-04 = 1 [StallP@Decel Enable = Enabled] and L3-50
= 1 [StallP@Decel Mode = Automatic Decel Reduction]. Usually it is not necessary to change
this setting.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the gain to suppress current and motor speed hunting during operation when L3-01 = 4
[StallP Mode@Accel = ILim Mode]. Usually it is not necessary to change this setting.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Suppresses current hunting during acceleration. Usually it is not necessary to change this setting.
Description
Description
Description
Description
Description
Description
12.8 L: PROTECTION
Default
(Range)
0 μF
(0 to 65000 μF)
Default
(Range)
60 ms
(0 - 5000 ms)
Default
(Range)
Determined by A1-02
(0.000 - 1.000 s)
Default
(Range)
0.00 Hz
(0.00 - 1.00 Hz)
Default
(Range)
Determined by A1-02
(0.0 - 100.0)
Default
(Range)
5 ms
(0 - 100 ms)