Driving quality, 200 v class, three-phase: 0.1 to 22 kw, 200 v class, single-phase: 0.1 to 4.0 kw, 400 v class, three-phase: 0.37 to 30 kw
Table of Contents

Advertisement

*1
The maximum wiring length between the drive and motor is:
• 2xxx, 4xxx: 20 m (65.6 ft)
• Bxxx: 10 m (32.8 ft)
Note:
• Use a braided shield cable for the drive and motor wiring or put the wires through a metal conduit.
• Keep the cable between the drive and motor and the grounding wire as short as possible.
4.
Use a cable clamp to ground the motor cable to the metal plate.
Note:
Make sure that the protective ground wire complies with technical specifications or local safety standards.
A - Braided shield cable
B - Metal plate
A - Grounding surface (Remove any
paint or sealant.)
B - Enclosure panel
C - Metal plate
D - Drive
E - Shielded wire
SIEPCYEUOQ2V01A Q2V Technical Manual
C - Cable clamp (conductive)
Figure 5.5 Ground the shield
F - Motor
G - Motor cable
H - Cable clamp
I - Grounding wire
Figure 5.6 Install a Drive with a Built-in EMC Filter
5.2 European Standards