L4: Speed Detection - Omron Q2V Series Technical Manual

Driving quality, 200 v class, three-phase: 0.1 to 22 kw, 200 v class, single-phase: 0.1 to 4.0 kw, 400 v class, three-phase: 0.37 to 30 kw
Table of Contents

Advertisement

12.8 L: PROTECTION
1 : Dec Time 2 (C1-04)

L4: SPEED DETECTION

L4 parameters set the output of signals to the MFDO terminals, for example frequency agree and speed detection.
L4-01: SpAgree Det.Level
No.
Name
(Hex.)
L4-01
SpAgree Det.Level
(0499)
Sets the level to detect speed agree or motor speed when H2-01 to H2-03 = F, 10, 13, 14 [NO,NC,CM
FuncSelection to DO2-O2C Func Selection = SpeedAgree1, USpeedAgree1, FreqDetect 1, FreqDetect 2].
L4-02: SpAgree Det.Width
No.
Name
(Hex.)
L4-02
SpAgree Det.Width
(049A)
Sets the width to detect speed agree or motor speed when H2-01 to H2-03 = F, 10, 13, 14 [NO,NC,CM
FuncSelection to DO2-O2C Func Selection = SpeedAgree1, USpeedAgree1, FreqDetect 1, FreqDetect 2].
L4-03: SpAgree Det.Level(+/-)
No.
Name
(Hex.)
L4-03
SpAgree Det.Level(+/-)
(049B)
Sets the level to detect speed agree or motor speed when H2-01 to H2-03 = 11, 12, 15, 16 [NO,NC,CM
FuncSelection to DO2-O2C Func Selection = SpeedAgree2, USpeedAgree2, FreqDetect 3, FreqDetect 4].
L4-04: SpAgree Det.Width(+/-)
No.
Name
(Hex.)
L4-04
SpAgree Det.Width(+/-)
(049C)
Sets the width to detect speed agree or motor speed when H2-01 to H2-03 = 11, 12, 15, 16 [NO,NC,CM
FuncSelection to DO2-O2C Func Selection = SpeedAgree2, USpeedAgree2, FreqDetect 3, FreqDetect 4].
L4-05: FrefLoss Det.Selection
No.
Name
(Hex.)
L4-05
FrefLoss Det.Selection
(049D)
Enables the detection of a loss of an analog frequency reference when MFAI terminals (AI1 and AI2) input the
frequency reference. Set H2-01 to H2-03 = 4B [MFDO Function Select = FreqRef Loss] to enable this function.
If the frequency reference is less than 10% in 400 ms, the drive detects frequency reference loss.
1 : Stop
656
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the level to detect speed agree or motor speed.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the width to detect speed agree or motor speed.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the level to detect speed agree or motor speed.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the width to detect speed agree or motor speed.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the operation when the drive detects a loss of frequency reference.
Figure 12.122 Detection of Frequency Reference Loss
Description
Description
Description
Description
Description
SIEPCYEUOQ2V01A Q2V Technical Manual
Default
(Range)
Determined by A1-02
(Determined by A1-02)
Default
(Range)
Determined by A1-02
(Determined by A1-02)
Default
(Range)
Determined by A1-02
(Determined by A1-02)
Default
(Range)
Determined by A1-02
(Determined by A1-02)
Default
(Range)
1
(1, 2)

Advertisement