Omron Q2V Series Technical Manual page 604

Driving quality, 200 v class, three-phase: 0.1 to 22 kw, 200 v class, single-phase: 0.1 to 4.0 kw, 400 v class, three-phase: 0.37 to 30 kw
Table of Contents

Advertisement

12.7 H: TERMINALS
30: @TorqueLimit
Setting Value
Function
30
During Torque Limit
Note:
Refer to
"L7: TORQUE LIMIT on page
32: TrqDetect1NO
Setting Value
Function
32
TrqDetect1NO
ON : The output current/torque is more than the torque value set with L6-02 [Trq Det1 Level], or
the level is less than the torque value set with L6-02 for longer than the time set with L6-03 [Trq
Det1 Time].
Note:
• When L6-01 ≥ 5, the drive will detect when the output current/torque is less than the detection level of L6-02 for longer than the time
set in L6-03.
• Refer to
"L6: TORQUE DETECTION on page
33: TrqDetect1NC
Setting Value
Function
33
TrqDetect1NC
Use [L6: TORQUE DETECTION] parameters to set torque detection.
OFF : The output current/torque is more than the torque value set with L6-02 [Trq Det1 Level], or
the level is less than the torque value set with L6-02 for longer than the time set with L6-03 [Trq
Det1 Time].
Note:
• When L6-01 ≥ 5, the drive will detect when the output current/torque is less than the detection level of L6-02 for longer than the time
set in L6-03.
• Refer to
"L6: TORQUE DETECTION on page
37: TrqDetect2NO
Setting Value
Function
37
TrqDetect2NO
Use [L6: TORQUE DETECTION] parameters to set torque detection.
ON : The output current/torque is more than the torque value set with L6-05 [Trq Det2 Level], or
the level is less than the torque value set with L6-05 for longer than the time set with L6-06 [Trq
Det2 Time].
Note:
• When L6-04 ≥ 5, the drive will detect when the output current/torque is less than the detection level of L6-05 for longer than the time
set in L6-06.
• Refer to
"L6: TORQUE DETECTION on page
38: TrqDetect2NC
Setting Value
Function
38
TrqDetect2NC
Use [L6: TORQUE DETECTION] parameters to set torque detection.
OFF : The output current/torque is more than the torque value set with L6-05 [Trq Det2 Level], or
the level is less than the torque value set with L6-05 for longer than the time set with L6-06 [Trq
Det2 Time].
604
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
The terminal activates when the torque reference is the torque limit set with L7 parameters or H3-02 or H3-10 [MFAI Function
Select].
665" for more information.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
The terminal activates when the drive detects overtorque or undertorque.
660" for more information.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
The terminal deactivates when the drive detects overtorque or undertorque.
660" for more information.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
The terminal activates when the drive detects overtorque or undertorque.
660" for more information.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
The terminal deactivates when the drive detects overtorque or undertorque.
Description
Description
Description
Description
Description
SIEPCYEUOQ2V01A Q2V Technical Manual