Omron Q2V Series Technical Manual page 559

Driving quality, 200 v class, three-phase: 0.1 to 22 kw, 200 v class, single-phase: 0.1 to 4.0 kw, 400 v class, three-phase: 0.37 to 30 kw
Table of Contents

Advertisement

F6-63: DNet Network MAC ID
No.
Name
(Hex.)
F6-63
DNet Network MAC ID
(03DE)
F6-64 to F6-67: DynOut.Ass109 P1 to P4
No.
Name
(Hex.)
F6-64 to F6-67
DynOut.Ass109 P1 to P4
(03DF - 03E2)
F6-68 to F6-71: DynIn.Ass159 P1 to 4
No.
Name
(Hex.)
F6-68 to F6-71
DynIn.Ass159 P1 to 4
(03E3, 03E4,
03C7, and 03C8)
F6-72: PowerLink Address
No.
Name
(Hex.)
F6-72
PowerLink Address
(081B)
F7-01: IP Address 1
No.
Name
(Hex.)
F7-01
IP Address 1
(03E5)
Note:
When F7-13 = 0 [Addr Mode@Startup = Static]:
• Use parameters F7-01 to F7-04 to set the IP Address. Be sure to set a different IP address for each drive on the network.
• Also set parameters F7-01 to F7-12.
F7-02: IP Address 2
No.
Name
(Hex.)
F7-02
IP Address 2
(03E6)
Note:
When F7-13 = 0 [Addr Mode@Startup = Static]:
• Use parameters F7-01 to F7-04 to set the IP Address. Be sure to set a different IP address for each drive on the network.
• Also set parameters F7-01 to F7-12.
F7-03: IP Address 3
No.
Name
(Hex.)
F7-03
IP Address 3
(03E7)
Note:
When F7-13 = 0 [Addr Mode@Startup = Static]:
• Use parameters F7-01 to F7-04 to set the IP Address. Be sure to set a different IP address for each drive on the network.
• Also set parameters F7-01 to F7-12.
SIEPCYEUOQ2V01A Q2V Technical Manual
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the function to see the actual DeviceNet MAC address using the keypad. This parameter
functions as a monitor only.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets Configurable Outputs 1 to 4 written to the Modbus register.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets Configurable Inputs 1 to 4 written to the Modbus register.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the node ID for PowerLink communication.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the first octet of the IP Address for the device that is connecting to the network. Restart the
drive after you change this parameter.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the second octet of the IP Address for the device that is connecting to the network. Restart the
drive after you change this parameter.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the third octet of the IP Address for the device that is connecting to the network. Restart the
drive after you change this parameter.
Description
Description
Description
Description
Description
Description
Description
12.6 F: OPTIONS
Default
(Range)
0
(0 - 63)
Default
(Range)
0000h
(0000h - FFFFh)
Default
(Range)
0000h
(0000h - FFFFh)
Default
(Range)
0
(0 - 255)
Default
(Range)
192
(0 - 255)
Default
(Range)
168
(0 - 255)
Default
(Range)
1
(0 - 255)
12