H4: Analog Outputs - Omron Q2V Series Technical Manual

Driving quality, 200 v class, three-phase: 0.1 to 22 kw, 200 v class, single-phase: 0.1 to 4.0 kw, 400 v class, three-phase: 0.37 to 30 kw
Table of Contents

Advertisement

11.9 H: TERMINALS
Setting Value
Function
8
TorqRef/Lim
9
FW Trq Lim
B
Rev Trq Lim
C
RegenTrqLim
D
GenerTrqLim
E
OvUntrq Level
F
PID Fbk
10
PID SetPoint
11
Diff PIDFbk
12
AcDcTimeGain
13
DCInjBrakCurr
14
StallPLev@Rn
15
OutFLowLimSel
16
Mot PTC Input
30
Q2pack AI1
31
Q2pack AI2

H4: ANALOG OUTPUTS

No.
Name
(Hex.)
H4-01
AO An.Out Select
(041D)
H4-02
AO An.Out Gain
(041E)
RUN
360
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Enters the torque reference if the motor rated torque is 100%. This setting is the torque limit for speed control.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Enters the forward torque limit if the motor rated torque is 100%.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Enters the load torque limit if the motor rated torque is 100%.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Enters the regenerative torque limit if the motor rated torque is 100%.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Enters the torque limit that is the same for all quadrants for forward, reverse, and regenerative operation if the
motor rated torque is 100%.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Enters a signal to adjust the overtorque/undertorque detection level.
Note:
Use this function with L6-01 [Torque Detection Selection 1]. This parameter functions as an alternative to L6-
02 [Torque Detection Level 1].
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Enter the PID feedback value as a percentage of the maximum output frequency.
Note:
Parameter A1-02 [Control Method] selects which parameter is the maximum output frequency.
• A1-02 ≠ 8 [EZ Vector]: E1-04 [Max Output Frequency]
• A1-02 = 8: E9-02 [Maximum Speed]
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Enters the PID setpoint as a percentage of the maximum output frequency.
Note:
Parameter A1-02 [Control Method] selects which parameter is the maximum output frequency.
• A1-02 ≠ 8 [EZ Vector]: E1-04 [Max Output Frequency]
• A1-02 = 8: E9-02 [Maximum Speed]
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Enters the PID differential feedback value if the full scale analog signal (10 V or 20 mA) is 100%.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Enters a signal to adjust the gain used for C1-01 to C1-08 [Acceleration/Deceleration Times 1 to 4] and C1-09
[Fast Stop Time] when the full scale analog signal (10 V or 20 mA) is 100%.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Enters a signal to adjust the current level used for DC Injection Braking when the drive rated output current is
100%.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Enters a signal to adjust the stall prevention level during run if the drive rated current is 100%.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Enters a signal to adjust the output frequency lower limit level as a percentage of the maximum output frequency.
Note:
Parameter A1-02 [Control Method] selects which parameter is the maximum output frequency.
• A1-02 ≠ 8 [EZ Vector]: E1-04 [Max Output Frequency]
• A1-02 = 8: E9-02 [Maximum Speed]
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Uses the motor Positive Temperature Coefficient (PTC) thermistor to prevent heat damage to the motor as a
percentage of the current value when the 10 V analog signal is input.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Use with Q2pack. Refer to the Q2pack online manual for more information.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Use with Q2pack. Refer to the Q2pack online manual for more information.
Description
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the monitoring number to be output from the MFAO terminal AO.
Set the x-xx part of the Ux-xx [Monitor]. For example, set H4-01 = 102 to monitor U1-
02 [Output Frequency].
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the gain of the monitor signal that is sent from MFAO terminal AO.
Sets the analog signal output level from the terminal AO at 10 V or 20 mA as 100%
when an output for monitoring items is 100%.
Description
SIEPCYEUOQ2V01A Q2V Technical Manual
Ref.
614
614
616
616
616
616
616
616
616
617
617
617
618
618
618
618
Default
Ref.
(Range)
102
619
(000 - 999)
100.0%
619
(-999.9 - +999.9%)