12.10 o: KEYPAD
o1-46: 3rdMon Area Setting
No.
Name
(Hex.)
3rdMon Area Setting
o1-46
(11C6)
RUN
o1-47: Trend Plot 1 Min Scale Value
No.
Name
(Hex.)
Trend Plot 1 Min Scale
o1-47
Value
(11C7)
RUN
o1-48: Trend Plot 1 Max Scale Value
No.
Name
(Hex.)
Trend Plot 1 Max Scale
o1-48
Value
(11C8)
RUN
o1-49: Trend Plot 2 Min Scale Value
No.
Name
(Hex.)
Trend Plot 2 Min Scale
o1-49
Value
(11C9)
RUN
o1-50: Trend Plot 2 Max Scale Value
No.
Name
(Hex.)
Trend Plot 2 Max Scale
o1-50
Value
(11CA)
RUN
o1-51: Trend Plot Time Scale Setting
No.
Name
(Hex.)
Trend Plot Time Scale
o1-51
Setting
(11CB)
RUN
o1-55: AnGauge Area Selection
No.
Name
(Hex.)
AnGauge Area Selection
o1-55
(11EE)
RUN
0 : + - Area (- o1-56 - o1-56 )
1 : + Area (0 - o1-56 )
o1-56: AnGauge Area Setting
No.
Name
(Hex.)
AnGauge Area Setting
o1-56
(11EF)
RUN
700
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the horizontal axis value used to display the monitor set in o1-26 [Cust.Monitor 3] as a bar
graph. This parameter is only available when using an LCD keypad.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the horizontal axis minimum value used to display the monitor set in o1-24 [Cust.Monitor 1]
as a trend plot. This parameter is only available when using an LCD keypad.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the horizontal axis maximum value used to display the monitor set in o1-24 [Cust.Monitor 1]
as a trend plot. This parameter is only available when using an LCD keypad.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the horizontal axis minimum value used to display the monitor set in o1-25 [Cust.Monitor 2]
as a trend plot. This parameter is only available when using an LCD keypad.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the horizontal axis maximum value used to display the monitor set in o1-25 [Cust.Monitor 2]
as a trend plot. This parameter is only available when using an LCD keypad.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the time scale (horizontal axis) to display the trend plot. When you change this setting, the
drive automatically adjusts the data sampling time. This parameter is only available when using
an LCD keypad.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the range used to display the monitor set in o1-24 [Custom Monitor 1] as an analog gauge.
This parameter is only available when using an LCD keypad.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the value used to display the monitor set in o1-24 [Cust.Monitor 1] as an analog meter. This
parameter is only available when using an LCD keypad.
Description
Description
Description
Description
Description
Description
Description
Description
SIEPCYEUOQ2V01A Q2V Technical Manual
Default
(Range)
100.0%
(0.0 - 100.0%)
Default
(Range)
-100.0%
(-300.0 - +300.0%)
Default
(Range)
100.0%
(-300.0 - +300.0%)
Default
(Range)
-100.0%
(-300.0 - +300.0%)
Default
(Range)
100.0%
(-300.0 - +300.0%)
Default
(Range)
300 s
(1 - 3600 s)
Default
(Range)
1
(0, 1)
Default
(Range)
100.0%
(0.0 - 100.0%)