12.7 H: TERMINALS
7C: Prg Lock
Setting Value
Function
7C
Prg Lock
You can continue to view parameter setting values when the terminal is OFF [Parameters Cannot be Edited].
ON : Program Lockout
OFF : Parameter Write Prohibit
7D: Drive OH2
Setting Value
Function
7D
Drive OH2
7E: Node Setup
Setting Value
Function
7E
Node Setup
7F: Comms Test
Setting Value
Function
7F
Comms Test
The Self-Diagnostics function connects the transmission terminal of the control terminal block to the reception
terminal. The function transmits the data that the drive sent to make sure that the drive can communicate correctly.
Note:
Refer to Modbus communications "Self-Diagnostics" for the self-diagnostics procedure.
90 to 96: Q2pack DI1 to 7
Setting Value
Function
90 - 96
Q2pack DI1 to 7
Note:
You cannot set values 90 to 96 for inverse output.
9F: Q2pack Disable
Setting Value
Function
9F
Q2pack Disable
Note:
Set A1-07 = 2 [Q2pack Enable = With DI] to use this function.
ON : Disabled
OFF : Enabled
101 to 19F: Inverse Input of 1 to 9F
Setting Value
Function
101 to 19F
Inverse Input of 1 to 9F
For example, to use the inverse input of 46 [ASR I Reset], set H1-xx = 146.
Note:
You cannot use inverse input for all functions.
586
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the command to prevent parameter changes when the terminal is OFF.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the drive to display an oH2 [Drive Overheat Warning] alarm when the input terminal is ON. The alarm does not have an
effect on drive operation.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the function in CANopen communications to start the Node Setup function to set the drive node address from the host
controller.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Set the function for the drive to self-test RS-485 serial communications operation.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets digital inputs used with Q2pack. Refer to the Q2pack online manual for more information.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets operation of the Q2pack program saved in the drive.
Sets the function of the selected MFDI to operate inversely. To select the function, enter "1xx", where the "xx" is the function
setting value.
Description
Description
Description
Description
Description
Description
Description
SIEPCYEUOQ2V01A Q2V Technical Manual