No.
Name
(Hex.)
H6-06
PO Mon.Selection
(0431)
RUN
H6-07
PO Freq.Scaling
(0432)
RUN
H6-08
PI Minimum Frequency
(043F)
H6-09
PO Volt.PhaseSync
Selection
(156E)

H7: VIRTUAL INPUT OUTPUT

No.
Name
(Hex.)
H7-00
Virtual MFIO Selection
(116F)
Expert
H7-01
Virtual In1 Select
Function
(1185)
Expert
H7-02
Virtual In2 Select
Function
(1186)
Expert
H7-03
Virtual In3 Select
Function
(1187)
Expert
H7-04
Virtual In4 Select
Function
(1188)
Expert
H7-10
Virtual Out1 Select
Function
(11A4)
Expert
H7-11
Virtual Out1 Delay Time
(11A5)
Expert
H7-12
Virtual Out2 Select
Function
(11A6)
Expert
H7-13
Virtual Out2 Delay Time
(11A7)
Expert
H7-14
Virtual Out3 Select
Function
(11A8)
Expert
H7-15
Virtual Out3 Delay Time
(11A9)
Expert
H7-16
Virtual Out4 Select
Function
(11AA)
Expert
H7-17
Virtual Out4 Delay Time
(11AB)
Expert
SIEPCYEUOQ2V01A Q2V Technical Manual
Description
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets a function for pulse train monitor output terminal PO. Sets the "x-xx" part of the
Ux-xx monitor.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the frequency of the pulse train output signal used when the monitor set with H6-
06 [PO Mon.Selection] is 100%.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the minimum frequency of the pulse train signal that terminal PI can detect.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Set whether to output the pulse synchronized with drive output voltage phase from the
pulse train monitor output terminal PO. This parameter is only enabled when H6-06 =
102 [PO Mon.Selection = Output Frequency] and H6-07 = 0 [PO Freq.Scaling = 0
Hz].
0 : Disabled
1 : Enabled
Description
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the function to enable and disable the virtual I/O function. Set this parameter to 1
to operate the virtual I/O function.
0 : Disabled
1 : Enabled
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the function that enters the virtual input set in H7-10 [Virtual Out1 Select
Function].
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the function that enters the virtual input set in H7-12 [Virtual Out2 Select
Function].
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the function that enters the virtual input set in H7-14 [Virtual Out3 Select
Function].
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the function that enters the virtual input set in H7-16 [Virtual Out4 Select
Function].
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the function for virtual digital output 1.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the minimum ON time for virtual digital output 1.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the function for virtual digital output 2.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the minimum ON time for virtual digital output 2.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the function for virtual digital output 3.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the minimum ON time for virtual digital output 3.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the function for virtual digital output 4.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the minimum ON time for virtual digital output 4.
11.9 H: TERMINALS
Default
Ref.
(Range)
102
626
(000, 031, 101, 102, 105,
116, 501, 502, 801 - 809,
821 - 825, 831 - 839, 851
- 855)
1440 Hz
627
(0 - 32000 Hz)
0.5 Hz
627
(0.1 - 1000.0 Hz)
0
627
(0, 1)
Default
Ref.
(Range)
0
628
(0, 1)
0
628
(0 - 4, 6 - 19F)
0
628
(0 - 4, 6 - 19F)
0
628
(0 - 4, 6 - 19F)
0
629
(0 - 4, 6 - 19F)
0
629
(0 - 1A7)
0.1 s
629
(0.0 - 25.0 s)
0
629
(0 - 1A7)
0.1 s
629
(0.0 - 25.0 s)
0
629
(0 - 1A7)
0.1 s
629
(0.0 - 25.0 s)
0
629
(0 - 1A7)
0.1 s
630
(0.0 - 25.0 s)
363
11

Advertisement

Table of Contents
loading

Table of Contents