11.9 H: TERMINALS
Setting Value
Function
11
SpeedAgree2
12
USpeedAgree2
13
FreqDetect 1
14
FreqDetect 2
15
FreqDetect 3
16
FreqDetect 3
17
@Fast Stop
18
@KEBridethru
19
@ShortCBraking
1A
@BaseblockNO
1B
@BaseblockNC
1C
FreqRefSource
356
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
The terminal activates when the output frequency is in the range of the frequency reference ± L4-04 [SpAgree Det.
Width(+/-)].
Note:
The detection function operates in the two motor rotation directions.
ON : The output frequency is in the range of "frequency reference ± L4-04".
OFF : The output frequency is not in the range of "frequency reference ± L4-04".
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
The terminal activates when the output frequency is in the range of L4-03 [SpAgree Det.Level(+/-)] ± L4-04
[SpAgree Det.Width(+/-)] and in the range of the frequency reference ± L4-04.
Note:
The detection level set with L4-03 is a signed value. The drive will only detect in one direction.
ON : The output frequency is in the range of "L4-03 ± L4-04" and the range of frequency reference ± L4-04.
OFF : The output frequency is not in the range of "L4-03 ± L4-04" nor the range of frequency reference ± L4-04.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
The terminal deactivates when the output frequency is higher than the value of L4-01 [SpAgree Det.Level] + L4-02
[SpAgree Det.Width]. After the terminal turns off, the terminal continues to remain off until the output frequency
reaches the level set with L4-01.
Note:
The detection function operates in the two motor rotation directions. The drive uses the L4-01 value as the
forward/reverse detection level.
ON : The output frequency is less than the value of L4-01 or does not exceed the value of L4-01 + L4-02.
OFF : The output frequency is higher than the value of L4-01 + L4-02.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
The terminal activates when the output frequency is higher than the value of L4-01 [SpAgree Det.Level]. After the
terminal activates, the terminal stays activated until the output frequency is at the value of L4-01 - L4-02.
Note:
The detection function operates in the two motor rotation directions. The drive uses the L4-01 value as the
forward/reverse detection level.
ON : The output frequency is higher than the value of L4-01.
OFF : The output frequency is less than the value of "L4-01 - L4-02," or it does not exceed the value of L4-01.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
The terminal deactivates when the output frequency is higher than the value of "L4-03 [SpAgree Det.Level(+/-)] +
L4-04 [SpAgree Det.Width(+/-)]". After the terminal deactivates, the terminal stays deactivated until the output
frequency is at the value of L4-03.
Note:
The detection level set with L4-03 is a signed value. The drive will only detect in one direction.
ON : The output frequency is less than the value of L4-03 or does not exceed the value of L4-03 + L4-04.
OFF : The output frequency is higher than the value of L4-03 + L4-04.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
The terminal activates when the output frequency is higher than the value of L4-03 [SpAgree Det.Level(+/-)]. After
the terminal activates, the terminal stays activated until the output frequency is at the value of L4-03 - L4-04.
Note:
The detection level set with L4-03 is a signed value. The drive will only detect in one direction.
ON : The output frequency is higher than the value of L4-03.
OFF : The output frequency is less than the value of "L4-03 - L4-04," or it does not exceed the value of L4-03.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
The terminal activates when the fast stop is in operation.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
The activates during KEB Ride-Thru.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
The terminal activates during Short Circuit Braking.
Note:
When A1-02 = 8 [Control Method = EZ Vector], this function is available when you use a PM motor.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
The terminal turns on during baseblock. When the drive is in baseblock, the drive output transistor stops switching
and does not make DC bus voltage.
ON : During baseblock
OFF : The drive is not in baseblock.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
The terminal deactivates during baseblock. When the drive is in baseblock, the drive output transistor stops
switching and does not make DC bus voltage.
ON : The drive is not in baseblock.
OFF : During baseblock
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Shows the selected frequency reference source.
ON : The keypad is the frequency reference source.
OFF : Parameter b1-01 or b1-15 [Freq. Ref. Sel. 1 or Freq. Ref. Sel. 2] is the frequency reference source.
Description
SIEPCYEUOQ2V01A Q2V Technical Manual
Ref.
599
599