Errors When Using The Digital Operator Copy Function - Omron SYSDRIVE 3G3RV Series User Manual

High-function general-purpose inverters
Table of Contents

Advertisement

Display
Meaning
Motor speed error
(detected only for
rotational autotuning)
Motor Speed
Current detection
error
I-det Circuit
Leakage inductance
error
Leak Inductance
V/f settings exces-
sive
*
V/f Over Setting
Motor core satura-
tion error (detected
only for rotational
autotuning)
Saturation
Rated current setting
*
alarm
Rated FLA Alm
* Displayed after autotuning has been completed.
K K K K

Errors when Using the Digital Operator Copy Function

The errors that can occur when using the copy function from the Digital Operator are given in the following
table. An error code will be displayed on the Digital Operator. If a Digital Operator key is pressed when an
error code is being displayed, the display will be cleared and 03-01 will be displayed. The error contact output
and alarm output will not function.
Table 7.4 Errors During Autotuning (Continued)
Probable causes
The torque reference was too high
(100%) during acceleration (for open
loop vector control only).
The current flow exceeded the motor
rated current.
The detected current sign was the oppo-
site of what it should be.
There is a phase fault for U, V, or W.
Autotuning was not completed in the
specified time.
The torque reference exceeded 100%
and the no-load torque exceeded 70%
during autotuning.
Autotuning for the motor core saturation
value could not be completed in the
specified time.
The results of autotuning has exceeded
the setting range for a parameter so a
temporary setting was made for the
motor core saturation coefficient.
The rated current is set high.
Protective and Diagnostic Functions
Corrective Actions
• If the motor is connected to the
machine, disconnect it.
• Increase C1-01 (Acceleration Time 1).
• Check the input data (particularly the
number of PG pulses and the number
of motor poles).
Check the current detection circuit,
motor wiring, current detector, and
installation methods.
Check motor wiring.
• Check and correct the settings.
• Disconnect the load from the motor.
• Check the input data.
• Check motor wiring.
• If the motor is connected to the
machine, disconnect it.
Check the input data (particularly the
motor output current and motor rated
current).