Nearly Empty Adjustment; Select Change Parameter; Select Scan Run; Select Nearly Empty - Kodak Miniloader 2000 Service Manual

Table of Contents

Advertisement

ADJUSTMENTS
3
.
Fasten the MOUNTING SCREWS.
4
.
Loosen the MOUNTING SCREWS of the CASSETTE LEVEL BRACKET.
Set the edge of CASSETTE LEVEL to a distance of 181 ±0.5 mm from the BASE
5
.
PLATE.
6
.
Fasten the MOUNTING SCREWS.
7
Start the SCAN RUN.
Start the SERVICE PROGRAM
Select SERVICE MODE from the GLOBAL MENU .......................... press ENTER
ENTER SERVICE MODE MESSAGE is displayed ............................ press ENTER
UNIT DATA are displayed....................................................................... press ENTER
Select change ML2000 DATA from the MAIN MENU .................... press ENTER
Select CHANGE PARAMETER .............................................................. press ENTER
Select SCAN RUN ..................................................................................... press ENTER
Select STORE PARAMETERS ................................................................ press ENTER
8
.
Do the NEARLY EMPTY adjustment.
Select NEARLY EMPTY........................................................................... press ENTER
9
.
Exit the SERVICE MODE
Select STORE PARAMETERS ................................................................ press ENTER
Press BACKSPACE twice
Select QUIT ML2000 SERVICE MODE ............................................... press ENTER
Select Quit the program ............................................................................ press ENTER
10.
Check the FILM POCKET ADJUSTMENT.

NEARLY EMPTY ADJUSTMENT

PURPOSE:
This adjustment finds automatically the correct value of NEARLY EMPTY.
1
.
Start the NEARLY EMPTY ADJUSTMENT
Start the SERVICE PROGRAM
Select SERVICE MODE from the GLOBAL MENU .......................... press ENTER
ENTER SERVICE MODE MESSAGE is displayed ............................ press ENTER
UNIT DATA are displayed....................................................................... press ENTER
Select CHANGE ML2000 DATA from the MAIN MENU ............... press ENTER
Select CHANGE PARAMETER .............................................................. press ENTER
Select NEARLY EMPTY........................................................................... press ENTER
2
.
Follow the instructions given on the LAP TOP SCREEN.
6/97
An empty MAGAZINE has to be used for this procedure.
NOTE
3-40
SM 3477
KODAK AG, Stuttgart

Advertisement

Table of Contents
loading

This manual is also suitable for:

Miniloader 2000 p