56.
Manually rotate the FILM POCKET SUCKER BAR out of the MAGAZINE.
57.
Test the position of the BLOW PIPE HOLES in relation to the FILM POCKET
SUCKERS. To do this the COMPRESSOR must be switched on,SOLENOID VALVE Y12
must be energised and SOLENOID TILTING MAGAZINE SUCKER BAR Y14 must be
switched on
Press BACKSPACE twice to come back to the screen COMPONENT TEST
Select MAGAZINE MOTORS................................................................. press ENTER
Select COMPRESSOR M16 ..................................................................... press ENTER
Select MOTOR ON
Press BACKSPACE twice to come back to the screen COMPONENT TEST
Select SOLENOID VALVES .................................................................... press ENTER
Select MAGAZINE SUCKING Y12 ....................................................... press ENTER
Select SOL: VALVE ON ........................................................................... press ENTER
Press BACKSPACE twice to come back to the screen COMPONENT TEST
Select SOLENOIDS ................................................................................... press ENTER
Select TILTING MAGAZINE SUCKER BAR Y14 ............................. press ENTER
Select SOLENOID ON
Do not leave on the SOLENOID Y14 for too long. It will become very hot.
KODAK AG, Stuttgart
.
figure 3-30
NOTE
3-27