Cassette Sucker Bar; How To Clean The Suckers - Kodak Miniloader 2000 Service Manual

Table of Contents

Advertisement

SM 3477
12.
Exit the SERVICE MODE.
Press BACKSPACE 3 times
Select LEAVE THE COMPONENT TEST ........................................... press ENTER
Select QUIT ML2000 SERVICE MODE ............................................... press ENTER
Select Quit the program ............................................................................ press ENTER

CASSETTE SUCKER BAR

Purpose:
This adjustment ensures that the CASSETTE SUCKER BAR CARRIAGE travels the correct
distance, that the rear end position is correct, and the CASSETTE SUCKERS are withdrawn
correctly from the film as it is picked up by the TRANSPORT ROLLERS to avoid static or
pressure marks.

How to clean the SUCKERS

The main cause of SUCKER MARKS is contamination of the sucker surface. This contamination
can be any number of substances ranging from natural body oil, sweat or even KODAK Intensifying
Screen Cleaner and anti static Solution (which has sometimes been recommended for cleaning
SUCKERS!). Do not use KODAK Intensifying Screen Cleaner and Anti Static Solution to clean the
SUCKERS! Use the following procedure if the SUCKERS are touched or if new ones are fitted.
1
.
Abrade the surface of the SUCKER carefully using Emery Cloth grade 400 or a
similar material.
2
.
Lightly coat the SUCKER with NATURAL (un-perfumed) talcum powder, available from
chemists and pharmacies.
Special Tools:
VERNIER CALLIPER
ADJUSTMENT PLATE TL 4804
PART 1
1
.
Take off the TOP PANEL.
KODAK AG, Stuttgart
NOTE
figure 3-5
3-5
ADJUSTMENTS
6/97

Advertisement

Table of Contents
loading

This manual is also suitable for:

Miniloader 2000 p

Table of Contents