SM 3477
TIME is started. When this time is terminated the vacuum is released and the FILM is picked
up by the TRANSPORT ROLLERS.
1 increment = 10 msec
RANGE: ...........................................................................................................00h...0Fh
DEFAULT: ......................................................................................................08h
1
.
Start CHANGE PARAMETER.
Start the SERVICE PROGRAM
Select SERVICE MODE from the GLOBAL MENU .......................... press ENTER
ENTER SERVICE MODE MESSAGE is displayed ............................ press ENTER
UNIT DATA are displayed....................................................................... press ENTER
Select CHANGE ML2000 DATA from the MAIN MENU ............... press ENTER
Select CHANGE PARAMETER .............................................................. press ENTER
Select VACUUM OFF TIME
Key in the new value.................................................................................. press ENTER
Select STORE PARAMETER .................................................................. press ENTER
2
.
Exit the SERVICE PROGRAM.
Press BACKSPACE twice
Select QUIT ML2000 SERVICE MODE ............................................... press ENTER
Select Quit the program ............................................................................ press ENTER

2. REST TIME

PURPOSE:
The CASSETTE OPENER is stopped for a short time. This allows the FILM to become
separated from the LID SCREEN.
1 increment = 10 msec
RANGE: ...........................................................................................................0h...FFh
DEFAULT: ......................................................................................................00h
1
.
Change REST TIME.
Start the SERVICE PROGRAM
Select SERVICE MODE from the GLOBAL MENU .......................... press ENTER
ENTER SERVICE MODE MESSAGE is displayed ............................ press ENTER
UNIT DATA are displayed....................................................................... press ENTER
Select CHANGE ML2000 DATA from the MAIN MENU ............... press ENTER
Select CHANGE PARAMETER .............................................................. press ENTER
Select REST TIME .................................................................................... press ENTER
Key in the new value.................................................................................. press ENTER
Select STORE PARAMETER .................................................................. press ENTER
2
.
Exit the SERVICE PROGRAM.
Press BACKSPACE twice
Select QUIT ML2000 SERVICE MODE ............................................... press ENTER
Select Quit the program ............................................................................ press ENTER
KODAK AG, Stuttgart
4-3
PARAMETER