Magazine Levels - Kodak Miniloader 2000 Service Manual

Table of Contents

Advertisement

PARAMETER
ENTER SERVICE MODE MESSAGE is displayed ............................ press ENTER
UNIT DATA are displayed....................................................................... press ENTER
Select CHANGE ML2000 DATA from the MAIN MENU ............... press ENTER
Select CHANGE PARAMETER .............................................................. press ENTER
Select LOWER POCKET ST ................................................................. press ENTER
Key in the new value.................................................................................. press ENTER
Select STORE PARAMETER .................................................................. press ENTER
2
.
Exit the SERVICE PROGRAM.
Press BACKSPACE twice
Select QUIT ML2000 SERVICE MODE ............................................... press ENTER
Select Quit the program ............................................................................ press ENTER

4. MAGAZINE LEVELS.

Purpose:
These values are used to transport the FILM POCKET to the correct level. One increment is
equal to 0.09 mm.
The VALUES in the table are just an example. They depend on the position of the LEVEL
BRACKETS. This means the values are not the same for every Miniloader. If the position of
a LEVEL BRACKET is changed a SCAN RUN must be performed.
After a SCAN RUN was performed do the nearly empty adjustment.
...........................................................................................................................EXAMPLE
MAGAZINE LEVEL 1 .....................................................................................1507D
MAGAZINE LEVEL 2 .....................................................................................2600D
MAGAZINE HOMEPOS .................................................................................2704D
GEAR BACKLASH..........................................................................................0006D
To change these values start the OPTION SCAN RUN of CHANGE PARAMETERS.
1
.
Start the SCAN RUN.
Start the SERVICE PROGRAM
Select SERVICE MODE from the GLOBAL MENU .......................... press ENTER
ENTER SERVICE MODE MESSAGE is displayed ............................ press ENTER
UNIT DATA are displayed....................................................................... press ENTER
Select CHANGE ML2000 DATA from the MAIN MENU ............... press ENTER
Select CHANGE PARAMETER .............................................................. press ENTER
Select SCAN RUN .................................................................................... press ENTER
Select STORE PARAMETER .................................................................. press ENTER
2
.
Exit the SERVICE PROGRAM.
Press BACKSPACE twice
Select QUIT ML2000 SERVICE MODE ............................................... press ENTER
Select Quit the program ............................................................................ press ENTER
6/1997
NOTE
4-8
SM 3477
KODAK AG, Stuttgart