Kodak Miniloader 2000 Service Manual page 26

Table of Contents

Advertisement

REPLACEMENTS
25.
Mount the CHAIN onto the MOTOR DRIVE GEAR and onto the SMALL GEAR.
26.
Put the small GEAR onto its SHAFT and secure it with the C-RING.
27.
Tension the CHAIN by moving the CASSETTE OPENER MOTOR to the right.
28.
Tighten the MOTOR MOUNTING SCREWS.
29.
Move the CASSETTE OPENER to its fully up position. Select UP until the OPENER
BRACKET is vertical.
30.
Adjust the ACTUATOR so that SENSOR B15 is actuated. Tighten its MOUNTING
SCREW.
31.
The ACTUATOR must now be set to a position that the CASSETTE OPENER
MOTOR is switched off as soon as the OPENER BRACKET is vertical. Select DOWN
until the OPENER is fully down Select UP until the OPENER stops.
32.
If the OPENER BRACKET is vertical proceed with step 33. If not, reposition the
ACTUATOR as required and proceed with step 31.
33.
SENSOR B15 is now adjusted correctly. The next step is to adjust the OPENER
STOP PLATE.
34.
The OPENER is still in the upper position. Turn the STOP PLATE counter-clockwise
until the STOP BOLT touches the STOP PIN of the DRIVE GEAR. Turn the STOP
PLATE clockwise until there is a gap of approximately 1 mm between the STOP PIN
and the STOP BOLT.
It is not possible to see this gap. You have to set it by feeling.
35.
Tighten the MOUNTING SCREWS of the STOP PLATE.
36.
Check the position of the STOP PLATE.
-Disconnect SENSOR B15.
-Select UP. The MOTOR M5 must turn for a short distance and is stopped then.
A high pitched tone can be heard at the same time.
-Connect SENSOR B15.
-Select DOWN until the CASSETTE OPENER stops in its bottom position.
-Manually actuate SENSOR B15. Do not break its thin PLASTIC ACTUATOR.
-Select DOWN again. MOTOR M5 should turn for a short distance and is stopped then.
A high pitched tone can be heard at the same time.
-Select UP until the CASSETTE OPENER stops in its uppermost position.
-If the UP and DOWN positions are correct, proceed with step 37. Otherwise reposition the
STOP PLATE and repeat step 33.
37.
Exit the SERVICE MODE.
Press BACKSPACE 3 times
Select LEAVE THE COMPONENT TEST .......................................... press ENTER
Select QUIT ML2000 SERVICE MODE ............................................... press ENTER
Select Quit the program ........................................................................... press ENTER
6/97
NOTE
2-16
SM 3477
KODAK AG, Stuttgart