Kodak Miniloader 2000 Service Manual page 76

Table of Contents

Advertisement

ADJUSTMENTS
Select FILM PICK UP MAGAZINE M15 ........................................... press ENTER
Select FORWARD
69.
If this distance is not correct, proceed with step 70 else proceed with step 74.
70.
Rotate out the FILM POCKET SUCKER BAR.
Select BACKWARD
71.
Loosen the MOUNTING SCREWS of the MAGAZINE LEVEL BRACKET and move it
up or down as required. Then fasten the MOUNTING SCREWS. See the drawing on the
next page
The gap given in figure 3-34 has to be correct. The distances given for the MAGAZINE LEVEL
72.
Do a SCAN RUN.
Select CHANGE ML2000 (ML2000 P) DATA ................................... press ENTER
Select CHANGE PARAMETER ............................................................. press ENTER
Select SCAN RUN .................................................................................... press ENTER
Select NEARLY EMPTY ......................................................................... press ENTER
Select STORE PARAMETERS ............................................................... press ENTER
Select RETURN TO MAIN MENU ...................................................... press ENTER
Select COMPONENT TEST ................................................................... press ENTER
Select MAGAZINE MOTORS ............................................................... press ENTER
73.
Proceed with step 75.
74.
Rotate out the FILM POCKET SUCKER BAR.
Select BACKWARD press ENTER
75.
Press Backspace to go back to the screen TEST MAGAZINE MOTORS.
76.
Insert the MAGAZINE into position 1.
6/97
.
ADJUSTMENT are just a starting point.
figure 3-34
NOTE
3-30
SM 3477
KODAK AG, Stuttgart

Advertisement

Table of Contents
loading

This manual is also suitable for:

Miniloader 2000 p

Table of Contents