7.13.5 Invalid time during control command execution

Menu
Top→PRESET COMMAND→INVALID TIME
Setting value 0s000ms to 999s999ms [Default]: 0s000ms
You can set the waiting time from starting control command execution to receiving the next command. Use
this menu to prevent repeated execution caused by pressing the control command execution key twice.
The longer time either of control command execution time or the time set in this menu will be applied as the
invalid operation time. Only operations from ports that execute control commands will be invalid; operations
from other ports can be performed. For example, if you execute a control command from the front panel, you
cannot perform all operations from the front panel until the control command execution time or time set in this
menu passes, but you can perform operations from the parallel input. However, even during invalid operation
time, for controlling power of sink devices and switching inputs, you can control sink devices' power and can
then switch input only for different outputs, in order to operate several outputs successively.

7.13.6 Initializing registered commands and associations

Menu
Top→PRESET COMMAND→INITIALIZE
Setting value
CMD 1 to CMD 32: control command
RCV 1 to RCV 32: reply command
POWER ON -: control command association
You can initialize the following commands and associations:
▪ Control commands registered in "7.13.1 Registering/editing control command (P.74) "
▪ Reply commands registered in "7.13.2 Registering/editing reply command (P.79)"
▪ Associations of control commands registered in "7.13.3 Command link (P.82)"
Use this menu to delete or set them from the first step again.
A long buzzer will sound when the initialization is completed by pressing the MENU/SET key.

7.13.7 Blinking time of sink device power switch

Menu
Top→PRESET COMMAND→FLASH TIME
Setting value
EXECUTION: Blinks while a control command is being executed [Default]
OFF: Not blink
1sec. to 1000sec.: Blinks for the specified time (1 to 1000 sec.)
You can set the blink time of command execution keys and power switch of sink devices during command
execution.
MSD-501/502/701/702 User's Guide
83