MSD-72 series Command Guide
@GIT / @SIT
Getting
Command
Response
Setting
Command
Response
Parameter
Getting
Command
example
Response
Description Getting ineffective time of control command execution.
Setting
Command
example
Response
Description Setting ineffective time during control command execution to 2000 ms. (2
Remarks
@DEC
Setting
Command
Response
Parameter
Setting
Command
example
Response
Description Deleting the link between COMMAND A and PLANE A.
Remarks
90
Ineffective time during control command execution
@GIT
@GIT, time
@SIT, time
@SIT, time
time: Invalid time
0 = 0 to 999999 = 999.999 seconds [Default] 0
@GIT
@GIT,2000
Disabling operation during control command execution or 2000 ms. (2 seconds)
after control command starts.
@SIT,2000
@SIT,2000
seconds).
Initializing registered command and link
@DEC, no_1 (, no_2, no_3・・・)
@DEC, no_1 (, no_2, no_3・・・)
no_1-32: Commands or links you want to initialize
1 to 32: Control commands1 to 32
101 to 132: Response commands1 to 32 ("1xx": xx is the response command
number)
201 to 308: Control command links1 to 108 ("2xx": xx is the control command
execution condition)
@DEC,201
@DEC,201
【See: @GRC / @SRC Response】
【See: @GCC / @SCC Control command link】