IDK MSD-72 Series Command Reference Manual page 92

Digital multi switcher
Hide thumbs Also See for MSD-72 Series:
Table of Contents

Advertisement

MSD-72 series Command Guide
@GTF / @STF
Getting
Command
Response
Setting
Command
Response
Parameter
Getting
Command
example
Response
Description
Setting
Command
example
Response
Description
Remarks
92
Blinking time of sink device power switch
@GTF, switch_1 (, switch_2・・・)
@GTF, switch_1, flash_1 (, switch_2, flash_2・・・)
@STF, switch_1, flash_1 (, switch_2, flash_2・・・)
@STF, switch_1, flash_1 (, switch_2, flash_2・・・)
switch_1-13: Switch type
0 = All switches, 1 = COMMAND A to 9 = COMMAND I
10 = DISPLAY1 POWER to 13 = DISPLAY4 POWER
flash_1-13: Blinking time
-1 = Blinks during control command execution,
0 = Not blink,
1 to 1000 = Blinks for 1 second to 1000 seconds
[Default]
COMMAND A to COMMAND I = 0,
DISPLAY1 POWER to DISPLAY4 POWER = -1
@GTF,1
@GTF,1,-1
Getting blinking time of COMMAND A.
The switch will be blinked while control command is being executed.
@STF,1,5
@STF,1,5
Setting COMMAND A to blink 5 seconds after control command execution starts.

Advertisement

Table of Contents
loading