IDK MSD-72 Series Command Reference Manual page 77

Digital multi switcher
Hide thumbs Also See for MSD-72 Series:
Table of Contents

Advertisement

@GLF / @SLF
Getting
Command
Response
Setting
Command
Response
Parameter
Getting
Command
example
Response
Description Getting mode settings of connection 3.
Setting
Command
example
Response
Description Setting connection 3 as follows:
Remarks
LAN communication mode
@GLF, connection
@GLF, connection, mode (, ip_1, ip_2, ip_3, ip_4, pjlink, tcp, password)
@SLF, connection, mode (, ip_1, ip_2, ip_3, ip_4, pjlink, tcp, password)
@SLF, connection, mode (, ip_1, ip_2, ip_3, ip_4, pjlink, tcp, password)
connection: Connection number
1 = connection 1 to 8 = connection 8
mode: Operation mode
0 = RECEIVER mode [Default], 1 = TRANSMITTER mode
ip_1: Upper bit of the destination IP address to ip_4: lower bit of the destination
IP address
0 to 255 = 8 bit (Decimal notation) [Default] 192.168.1.198
Available only if the mode is TRANSMITTER.
pjlink: PJLink protocol connection
0 = PJLink not used [Default], 1 = PJLink used
Available only if the mode is TRANSMITTER.
tcp: Destination port number
1 to 65535 [Default] 1100
Available only if the mode is TRANSMITTER and "pjlink" is set to "0" (PJLink not
used).
If "pjlink" is set to "1" (PJLink used), "tcp" is "4352" fixed.
password: Password of PJLink protocol
Up to 32 characters of the following ASCII codes: 20, 30 to 39, 41 to 5A, 61
to 7A (alphanumeric characters). [Default] All: 20 (space)
Replied/Set only if the mode is "1" (TRANSMITTER) and pjlink is "0" (PJLink
not used).
Getting commands: replied only if the password is set.
Setting commands: you can skip this password setting if you disable password
authentication for PJLink protocol connection.
Available only if the mode is TRANSMITTER and "pjlink" is set to "0" (PJLink not
used).
Getting commands: returned only if the password is set.
Setting commands: you can skip this password setting if you do not use
password authentication for PJLink protocol connection.
@GLF,3
@GLF,3,1,192,168,1,2,1,PROJECTOR1
Mode = TRANSMITTER mode, destination IP address = 192.168.1.2,
PJLink = to be used, password = "PROJECTOR1"
@SLF,3,1,192,168,1,2,1
@SLF,3,1,192,168,1,2,1
Mode = TRANSMITTER mode, destination IP address = 192.168.1.2,
PJLink = to be used, password = disabling password authentication.
If IP address or RS-232C communication setting is changed, the communication
may be disabled. Change the environmental settings based on the MSD
settings.