MSD-72 series Command Guide
@GEC / @SEC
Getting
Command
Response
Setting
Command
Response
Parameter
Getting
Command
example
Response
Description
Setting
Command
example
Response
Description
Remarks
84
Control command (contact closure)
@GEC, no
@GEC, no, delay, port, memo, ccno_1, cc_1, pulse_1 (, ccno_2, cc_2,
pulse_2・・・)
@SEC, no, delay, port, memo, ccno_1, cc_1, pulse_1 (, ccno_2, cc_2,
pulse_2・・・)
@SEC, no, delay, port, memo, ccno_1, cc_1, pulse_1 (, ccno_2, cc_2,
pulse_2・・・)
no: Control command number
1 to 32
delay: Delay time
0 = 0 to 999999 = 999.999 seconds
port: Contact closure control
2048 = For contact closure control
memo
Up to 14 characters of 20 to 7D except 2C (,) from ASCII codes.
ccno_1-9: Contact closure number
ccno
1
2
CONTACT CLOSURE
Contact
1
closure
CH1
CH2
cc_1-9: Contact closure control
0 = OFF, 1 = ON, 2 = Toggle, 3 = Not control
pulse_1-9: pulse width
0 = Hold, 100 = 100 ms to 9990 = 9990 ms (by 10 ms)
Pulse width after the completion of contact closure.
Getting commands: only contact closure numbers to be controlled are replied.
Setting commands: specify only contact closure numbers to be controlled. For
contact closure numbers that do not specify parameter, "Not check" is set.
@GEC,7
@GEC,7,20,2048,SCREEN UP,1,1,100
Getting settings of control command 7.
・Delay time: 20ms
・Memo: SCREEN UP
・Contact closure1's CH1: ON for 100 ms
・Other outputs: not controlled.
@SEC,6,50,2048,PROJECTOR ON,1,0,200,2,1,0
@SEC,6,50,2048,PROJECTOR ON,1,0,200,2,1,0
Setting Control command number 6 as follows:
・Delay time: 50 ms
・Memo: PROJECTOR ON
・Contact closure1's CH1: ON for 200 ms
・Contact closure1's CH2: ON
・Other contact closures: not controlled.
3
4
5
CONTACT CLOSURE
2
CH3
CH1
CH2
CH3
6
7
8
9
CONTACT CLOSURE
3
CH1
CH2
CH3

Advertisement

Table of Contents
loading

Table of Contents