Rs-232C Communication Specification - IDK MSD-72 Series Command Reference Manual

Digital multi switcher
Hide thumbs Also See for MSD-72 Series:
Table of Contents

Advertisement

3-pin Terminal block RS-232C ports
Fix RS-232C cable to the attached 3-pin terminal block, and then connect it to the MSD.
AWG28 to AWG16 conductor gauge is recommended. The recommended wire strip length is 7 mm/0.28 inch.
If it is connected to a D-sub9 pin, cut RTS, CTS, DTR, and DSR (unused) as needed.
[Figure 2.2] Connecting RS-232C cable to 3-pin terminal block connector

2.1.2 RS-232C communication specification

Standard
Baud rate [bps]
Data bit length [bit]
Parity check
Stop bit [bit]
X parameter
Flow control
Delimiter
Communication method
RS-232C Tx
RS-232C Rx
GND
[Table 2.2] RS-232C specification
RS-232C
4800 / 9600 / 19200 / 38400 [bps]
7 / 8
NONE, EVEN, ODD
1 / 2
Invalid
None
CR LF (Carriage return and line feed, 0D and 0A in hex)
Full duplex
MSD-72 series Command Guide
Up to 7 mm (0.28 inch approx.)
Tx
Rx
GND
7

Advertisement

Table of Contents
loading

Table of Contents