MSD-72 series Command Guide
@STT
Setting
Command
Response
Parameter
Setting
Command
example
Response
Description Saving IN8 input timing setting in device table 2 without editing the device table
Setting
Command
example
Response
Description Saving the current IN8 input timing setting in device table 2 with the name of
Remarks
@GTK / @STK
Getting
Command
Response
Setting
Command
Response
Parameter
Getting
Command
example
Response
Description Getting the set tracking.
Setting
Command
example
Response
Description Setting IN8 tracking to "4".
Remarks
50
Registering device data
@STT, ch, table (, name)
@STT, ch, table (, name)
ch: Input channel
8 = IN8, 9 = IN9
table: Device table
1 to 99
name: Device table name
Up to 14 characters from 20 to 7D of ASCII code.
You can skip "Device table name". If you skip it, only input timing setting is
saved. However, if no device table name is currently saved, the resolution is
saved automatically as the device table name.
@STT,8,2
@STT,8,2
name.
@STT,8,2,XGA 60Hz
@STT,8,2,XGA 60Hz
"XGA 60Hz".
This command is valid only if analog RGB / YPbPr signal is input.
Tracking
@GTK
@GTK, track_1, track_2
@STK, ch_1, track_1 (, ch_2 , track_2)
@STK, ch_1, track_1 (, ch_2 , track_2)
track_1-2: Tracking
0 to 63 [Default] 0
ch_1-2: Input channel
0 = All analog inputs, 8 = IN8, 9 = IN9
@GTK
@GTK,4,0
If no analog RGB / YPbPr signal is input, "0" is returned.
@STK,8,4
@STK,8,4
This command is valid only if analog RGB / YPbPr signal is input. If "1" (Digital