Saturation
@GST
@GST, saturation_1, saturation_2, saturation_3, saturation_4, saturation_5,
saturation_6, saturation_7, saturation_8, saturation_9
@SST, ch_1, saturation_1 (, ch_2, saturation_2・・・)
@SST, ch_1, saturation_1 (, ch_2, saturation_2・・・)
saturation_1-9: Input saturation
0 to 200 [Default] 100
ch_1-9: Input channel
0 = All inputs, 1 = IN1 to 9 = IN9
@GST
@GST,100,100,100,100,105,100,100,100,100
Getting the set saturations.
IN5: 105%, other inputs: 100%
@SST,5,105
@SST,5,105
Setting IN5 saturation to 105%.
Saturation can be set up to 200%. If an input signal dot clock exceeds 170 MHz,
the MSD operates with the saturation of 100%.
Black level
@GSU
@GSU, setup_1, setup_2, setup_3, setup_4, setup_5, setup_6, setup_7,
setup_8, setup_9
@SSU, ch_1, setup_1 (, ch_2, setup_2・・・)
@SSU, ch_1, setup_1 (, ch_2, setup_2・・・)
setup_1-9: Input black level
-20 = -20 × 0.5 (-10.0%) to +20 = +20 × 0.5 (+10.0%)
[Default] ±0 = ±0.0%
ch_1-9: Input channel
0 = All inputs, 1 = IN1 to 9 = IN9
@GSU
@GSU,0,0,0,0,15,0,0,0,0
Getting the input black level.
IN5: +7.5%, other inputs: 0%.
@SSU,5,15
@SSU,5,15
Setting the IN5 black level to +7.5%.