76
 The length in mm sewn in the seam is displayed.
When the thread is cut, the display is reset.
You can also change parameters while in the middle of a seam.
This is how you change parameters in the middle of a seam:
1.
Press Pedal to position 0.
2.
Change the desired parameter on the control
panel ( p. 72).
3.
Press the pedal forwards again and sew.
 The seam will be sewn using the altered parameter value.
6.4

Automatic mode AUTO

Fig. 47: Automatic mode AUTO
(1) - Header
(2) - Left pane
Header (1)
The AUTO operating mode is displayed. The buttons + F% and
- F% offer quick access for setting the fullness values in %.
Settings via software (OP7000)
(3) - Middle pane
(4) - Right pane