Troubleshooting
Code
Type
2180
Error
2181
Error
2182
Error
2183
Error
2184
Error
2185
Error
2186
Error
2187
Error
2188
Error
Operating Instructions 650-10 - 03.0 - 08/2016
Possible causes
Direction of rotation
Error in the reference run
Stepper motor current error
Stepper motor overcurrent
Software error
Stepper motor insulation
error
Software error
Software error
Software error
Remedial action
• Replace the encoder
• Check plug assignment and
change, if necessary
• Check wiring in machine
distributor and change it,
if necessary
• Test stepper motor phases
and check for correct value
• Replace the reference
switch
• Remove the blockage
• Check the encoder cable
and replace, if necessary
• Replace the stepper motor
• Replace the sewing motor
cable
• Replace the stepper motor
• Replace the control
• Perform reset
• Perform a software update
• Contact customer service
• Check motor phase and
PE for low-impedance
connection
• Replace the encoder
• Replace the stepper motor
• Perform reset
• Perform a software update
• Contact customer service
• Perform reset
• Perform a software update
• Contact customer service
• Perform reset
• Perform a software update
• Contact customer service