Service settings via software (OP3000)
Operating Instructions 650-10 - 03.0 - 08/2016
5.3

Manual mode

Fig. 17: Manual mode
The following table shows the individual symbols (parameters) on
the display and the functions of the keys on the control panel.
When a parameter is selected, its color on the display changes.
When a parameter is changed, its new value is loaded immedia-
tely.
Symbol
Meaning
(depending on the assignment)
Quick programming
• Press the upper softkey ( p. 50)
Quick access function (softkey menu)
• Press the lower softkey ( p. 42)
Program number
Value range: 000 – 999
Program 000 indicates that the controller is in "Manual
mode".
• Use
• Use
Or:
• Input the program number directly using one of the
numeric keys
0 – 9 and confirm with OK as required
 The controller switches to Automatic mode
Fullness
Value range: Upper fullness: 0 – 16
• Use the numeric keys 0 – 16 to select the desired
fullness
• Use the plus/minus key to select upper or lower
fullness
Or:
• Use the additional pedal to select the fullness, if fitted
/
to select the parameter
/
to change the program number.
Lower fullness: 0 – 6