Code
Type
6000
Error
6299
6351
Error
6354
6400
Error
6999
7551
Error
7659
9910
Error
154
Possible causes
Internal error
Controller defective (I²C)
Internal error
• Internal error
• Cable disturbance
• Cables to the control panel
Interface defective
Tilt sensor:
• Machine head is tilted over
• Tilt sensor not fitted or
defective
Operating Instructions 650-10 - 03.0 - 08/2016
Troubleshooting
Remedial action
• Switch the machine off and
on again
• Perform a software update
• Contact customer service
• Replace the control
• Switch the machine off and
on again
• Perform a software update
• Contact customer service
• Switch the machine off and
on again
• Eliminate source of
disturbance
• Perform a software update
• Replace the cable
• Contact customer service
• Erecting the machine head
• Fit or replace tilt sensor