Changing The Needle - DURKOPP ADLER 650-10 Operating Instructions Manual

Hide thumbs Also See for 650-10:
Table of Contents

Advertisement

Operation
Operating Instructions 650-10 - 03.0 - 08/2016
4.3

Changing the needle

CAUTION
Risk of injury from sharp parts!
Punctures possible.
Switch off the machine before changing the
needle.
Fig. 3: Changing the needle
(1) - Needle bar
(2) - Screw
Change the needle as follows:
1.
Loosen the screw (2) and remove the needle.
2.
Insert the new needle into the hole in the needle bar (1) until
it reaches the end stop.
Important
The groove (4) must face towards the hook tip (3).
3.
Tighten the screw (2).
(3) - Hook tip
(4) - Groove