Type
1000
Error
1001
Error
1002
Error
1004
Error
1005
Error
138

11.2 Messages of the software

Please contact customer service if an error occurs that is not
described here. Do not attempt to correct the error yourself!
Table of software messages
Possible causes
Sewing motor error:
• Encoder plug (Sub-D,
9-pin) not connected or
defective
• Encoder defective
Sewing motor error:
• Sewing motor plug not
connected or defective
Sewing motor insulation error • Check motor phase and
Sewing motor error:
• Incorrect direction of
rotation
Sewing motor current error:
• Sewing motor blocked
• Encoder cable not
connected or defective
• Encoder defective
Remedial action
• Check the connection of
the encoder cable and
replace, if necessary
• Check the connection of
the sewing motor cable
• Test sewing motor phases
(R = 2.8Ω, high impedance
to PE)
• Replace the encoder
• Replace the sewing motor
• Replace the control
PE for low-impedance
connection
• Replace the encoder
• Replace the sewing motor
• Replace the encoder
• Check plug assignment and
change, if necessary
• Check wiring in machine
distributor and change it, if
necessary
• Test motor phases and
check for correct value
• Remove the blockage
• Check the encoder cable
and replace, if necessary
• Replace the sewing motor