Troubleshooting
Code
Type
1006
Error
1007
Error
1008
Error
1010
Error
1011
Error
1012
Error
1051
Error
1052
Error
1053
Error
1054
Error
Operating Instructions 650-10 - 03.0 - 08/2016
Possible causes
Sewing motor error:
• Max. speed exceeded
• Sewing motor cable
defective
• Sewing motor defective
Error in the reference run
Sewing motor encoder error
Sewing motor synchroniza-
tion error:
• External synchronizer
plug (Sub-D, 9-pin) not
connected
Sewing motor synchroniza-
tion error (Z pulse)
Sewing motor synchroniza-
tion error
Sewing motor timeout:
• Cable to sewing motor
Reference switch defective
• Reference switch defective
Sewing motor overcurrent:
• Sewing motor cable
defective
• Sewing motor defective
• Controller defective
Sewing motor overvoltage
Internal short circuit
Remedial action
• Switch the machine off and
on again
• Replace the encoder
• Perform reset
• Replace the sewing motor
• Contact customer service
• Replace the encoder
• Eliminate stiff movement in
the machine
• Replace the encoder
• Connect plug of external
synchronizer to controller,
use correct connection
(Sync)
• Replace the reference
switch or synchronizer
• Only required for machines
with transmission!
• Switch off the controller,
use handwheel to turn and
switch on the controller
again
• If error is not corrected,
check encoder
• Replace the synchronizer
• Replace the cable
• Replace the reference
switch
• Replace the sewing motor
cable
• Replace the sewing motor
• Replace the control
• Check the mains voltage
• Replace the control