Code
Type
2262
Error
2271
Error
2272
Error
2273
Error
2274
Error
2275
Error
2277
Error
2278
Error
2279
Error
Operating Instructions 650-10 - 03.0 - 08/2016
Possible causes
Y-axis stepper motor
disturbance (IDMA auto
increment)
Watchdog
Stepper motor overvoltage:
• Stepper motor card
defective
Y-axis stepper motor error
Software error
Magnet wheel search
Stepper motor overload (I²T) • Remove the cause of the
Encoder error
Current sensor:
• Stepper motor card
defective
• Controller defective
Remedial action
• Switch the machine off and
on again
• Switch the machine off and
on again
• Perform a software update
• Contact customer service
• Replace the control
• Check the connection
• Test stepper motor phases
(R = 2.8Ω, high impedance
to PE)
• Replace the encoder
• Replace the stepper motor
• Replace the control
• Perform reset
• Perform a software update
• Contact customer service
• Check the connection
• Test stepper motor phases
(R = 2.8Ω, high impedance
to PE)
• Replace the encoder
• Replace the stepper motor
• Replace the control
stiff movement or blockage
• Replace the stepper motor
• Replace the control
• Check the connection of
the encoder cable and
replace, if necessary
• Replace the control
• Replace the control