11.2 Messages of the software
Error
code
Sewing motor
1051
1052
1053
1055
1056
1058
1302
1342
1344
Stepper motors
2101
2102
2152
2153
2155
161
Description
Sewing motor timeout
• Cable to sewing motor reference
switch defective
• Reference switch defective
• Machine head does not move freely
or has excessive toothed belt
tension
Sewing motor excess current
• Sewing motor cable defective
• Sewing motor defective
• Control defective
Sewing motor line voltage too high
Sewing motor overload
• Sewing motor blocked/not moving
freely
• Sewing motor defective
• Control defective
Sewing motor overtemperature
• Sewing motor not moving freely
• Sewing motor defective
• Control defective
Sewing motor speed
• Sewing motor defective
Sewing motor error
Control not receiving pulses from
pulse encoder in motor
Sewing motor error
Internal error
X-axis stepper motor referencing
timeout
• Faulty reference switch setting
• Faulty cable to the reference switch
• Reference switch defective
X-axis stepper motor current error
• Stepper motor blocked
• Encoder cable not connected or
defective
• Encoder defective
X-axis stepper motor excess current
X-axis stepper motor overvoltage
• Too high line voltage
X-axis stepper motor overload
• Feed system not moving freely
• Obstacle to feed motion
Troubleshooting
Troubleshooting
• Replace the cable
• Replace the reference switch
• Check the ease of movement and
toothed belt tension of the machine
head
• Replace the sewing motor cable
• Replace the sewing motor
• Replace the control
Check the line voltage
• Fix blockage/sluggishness
• Check the sewing motor
• Check the control
• Eliminate seizing
• Replace the sewing motor
• Replace the control
• Replace the sewing motor
• Check the cable from the pulse
encoder in the motor to the control
• Switch off and on the machine
again
• Software update
• Adjust reference switch
• Replace the cable
• Check the reference switch
• Fix blockage
• Check/replace the encoder cable
• Replace the stepper motor
• Replace the stepper motor
• Replace the control
• Check the line voltage
• Eliminate sluggishness
• Remove obstacles/adjust the motion
Service Instructions 911-211 - 02.0 - 10/2016