Advertisement

11.2 Messages of the software

Error
code
Sewing motor
1051
1052
1053
1055
1056
1058
1302
1342
1344
Stepper motors
2101
2102
2152
2153
2155
161
Description
Sewing motor timeout
• Cable to sewing motor reference
switch defective
• Reference switch defective
• Machine head does not move freely
or has excessive toothed belt
tension
Sewing motor excess current
• Sewing motor cable defective
• Sewing motor defective
• Control defective
Sewing motor line voltage too high
Sewing motor overload
• Sewing motor blocked/not moving
freely
• Sewing motor defective
• Control defective
Sewing motor overtemperature
• Sewing motor not moving freely
• Sewing motor defective
• Control defective
Sewing motor speed
• Sewing motor defective
Sewing motor error
Control not receiving pulses from
pulse encoder in motor
Sewing motor error
Internal error
X-axis stepper motor referencing
timeout
• Faulty reference switch setting
• Faulty cable to the reference switch
• Reference switch defective
X-axis stepper motor current error
• Stepper motor blocked
• Encoder cable not connected or
defective
• Encoder defective
X-axis stepper motor excess current
X-axis stepper motor overvoltage
• Too high line voltage
X-axis stepper motor overload
• Feed system not moving freely
• Obstacle to feed motion
Troubleshooting
Troubleshooting
• Replace the cable
• Replace the reference switch
• Check the ease of movement and
toothed belt tension of the machine
head
• Replace the sewing motor cable
• Replace the sewing motor
• Replace the control
Check the line voltage
• Fix blockage/sluggishness
• Check the sewing motor
• Check the control
• Eliminate seizing
• Replace the sewing motor
• Replace the control
• Replace the sewing motor
• Check the cable from the pulse
encoder in the motor to the control
• Switch off and on the machine
again
• Software update
• Adjust reference switch
• Replace the cable
• Check the reference switch
• Fix blockage
• Check/replace the encoder cable
• Replace the stepper motor
• Replace the stepper motor
• Replace the control
• Check the line voltage
• Eliminate sluggishness
• Remove obstacles/adjust the motion