Refitting Axis-6 Motor And Wrist Unit - ABB IRB 2600 Series Product Manual

Hide thumbs Also See for IRB 2600 Series:
Table of Contents

Advertisement

Refitting axis-6 motor and wrist unit

Use this procedure to refit the axis-6 motor and the wrist unit.
Refitting the motor
1
2
3
Product manual - IRB 2600
3HAC035504-001 Revision: Q
4.7.4 Replacing motor axis 6 and wrist unit - IRB 2600ID
Action
Place the motor axis into the axis-6 flexible
coupling.
Secure the motor with its attachment
screws.
Secure the motor axis with the flexible
coupling with its attachment screw.
© Copyright 2009-2018 ABB. All rights reserved.
Information
xx1000000929
Parts:
A Attachment screws, bracket
B Flexible coupling
C Attachment screws, motor (3 pcs)
D Cylindrical pins (2 pcs)
E Motor axis 6
Tightening torque: 6 Nm.
Tightening torque: 15 Nm.
B
A
C
xx1000000930
Parts:
A Attachment screw, coupling
B Flexible coupling
C Motor axis 6
Continues on next page