Storage Conditions, Robot; Operating Conditions, Robot - ABB IRB 2600 Series Product Manual

Hide thumbs Also See for IRB 2600 Series:
Table of Contents

Advertisement

Requirement
Minimum resonance
frequency
i

Storage conditions, robot

The table shows the allowed storage conditions for the robot:
Parameter
Minimum ambient temperature
Maximum ambient temperature
Maximum ambient temperature (less than 24 hrs)
Maximum ambient humidity

Operating conditions, robot

The table shows the allowed operating conditions for the robot:
Parameter
Minimum ambient temperature
Maximum ambient temperature
Maximum ambient humidity
Protection classes, robot
The table shows the available protection types of the robot, with the corresponding
protection class.
Protection type
Manipulator, protection type Standard
Manipulator, protection type Foundry Plus
Product manual - IRB 2600
3HAC035504-001 Revision: Q
Value
25 Hz
It may affect the
manipulator life-
time to have a
lower resonance
frequency than
recommended.
The minimum resonance frequency given should be interpreted as the frequency of the robot
mass/inertia, robot assumed stiff, when a foundation translational/torsional elasticity is added, i.e.,
the stiffness of the pedestal where the robot is mounted. The minimum resonance frequency should
not be interpreted as the resonance frequency of the building, floor etc. For example, if the equivalent
mass of the floor is very high, it will not affect robot movement, even if the frequency is well below
the stated 25 Hz. The robot should be mounted as rigid as possibly to the floor.
Disturbances from other machinery will affect the robot and the tool accuracy. The robot has
resonance frequencies in the region 10 – 20 Hz and disturbances in this region will be amplified,
although somewhat damped by the servo control. This might be a problem, depending on the
requirements from the applications. If this is a problem, the robot needs to be isolated from the
environment.
© Copyright 2009-2018 ABB. All rights reserved.
2 Installation and commissioning
2.2.1 Pre-installation procedure
Note
The value is recommended for optimal perform-
ance.
Due to foundation stiffness, consider robot mass
Note
including equipment.
For information about compensating for founda-
tion flexibility, see Application manual - Control-
ler software IRC5, section Motion Process Mode.
Value
-25° C
+55° C
+70° C
95% at constant temperature
(gaseous only)
Value
+5°C
+45°C
95% at constant temperature
Protection class
IRB 2600: IP 67
IRB 2600ID upper arm: IP 54
IP 67
Continued
i
53

Advertisement

Table of Contents
loading

Table of Contents