Table 20.5 Serial Communication Interface (Sci) Timing - Renesas H8 Series Hardware Manual

16-bit single-chip microcomputer
Hide thumbs Also See for H8 Series:
Table of Contents

Advertisement

Table 20.5 Serial Communication Interface (SCI) Timing

V
= 3.0 to 5.5 V, V
CC
Item
Input
Asynchro-
clock
nous
cycle
Clocked
synchro-
nous
Input clock pulse
width
Transmit data delay
time (clocked
synchronous)
Receive data setup
time (clocked
synchronous)
Receive data hold
time (clocked
synchronous)
= 0.0 V, T
= –20 to +75°C, unless otherwise indicated.
SS
a
Applicable
Symbol
Pins
t
SCK3
Scyc
t
SCK3
SCKW
t
TXD
TXD
t
RXD
RXS
t
RXD
RXH
Test Condition
Min
4
6
0.4
V
= 4.0 V to 5.5 V
CC
V
= 4.0 V to 5.5 V
50.0
CC
100.0 —
V
= 4.0 V to 5.5 V
50.0
CC
100.0 —
Rev. 1.00 Aug. 28, 2006 Page 329 of 400
Section 20 Electrical Characteristics
Values
Typ Max Unit
t
cyc
0.6
t
Scyc
1
t
cyc
1
ns
ns
REJ09B0268-0100
Reference
Figure
Figure 20.5
Figure 20.6

Advertisement

Table of Contents