Preparing The Acceptance Test - Siemens SINAMICS S120 Function Manual

Safety integrated
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

7.3.2

Preparing the acceptance test

Establishing an overview of all drives
1. Click "Acceptance test" in the project tree.
2. Select the "Overview" screen form in the secondary navigation.
3. Click "Determine" to determine all drives with Safety Integrated Functions in your
Startdrive project.
4. The overview window lists all available drives with Safety Integrated Functions as well as
their respective test status.
Color coding of the test status:
– Gray: Safety Integrated Functions have been parameterized, but the acceptance test
– Red: Acceptance test failed
– Blue: Acceptance test in the initial state
– Green: Acceptance test successful
5. Click "Output" to generate an overview as a table in "xlsx" format. You can open this table
in Microsoft Excel and other spreadsheet programs (e.g. LibreOffice).
You can use the overview to track and/or document your work progress, especially for
projects with several drives.
Preparing the acceptance test
1. The drives to be tested have been fully parameterized and commissioned. Subsequent
changes require performing a new acceptance test.
2. Click "Acceptance test" in the project tree.
Those Safety Integrated Functions available in the drive unit are offered for selection.
Whereby, the selection considers whether Basic Functions, Extended Functions or
Advanced Functions were selected as well as the activation type (PROFIsafe or onboard
terminals).
3. Select in the secondary navigation for the desired drive unit all Safety Integrated
Functions to be tested.
The active functions are preselected automatically. This preselection can be changed and
functions selected or deselected.
4. Click "Accept" to specify the function selection for the Safety Integrated acceptance test.
Entries for the functions to be tested are displayed in the secondary navigation. Navigate
with these settings to the individual tests.
5. Establish an online connection to the drive unit to be tested.
Safety Integrated
Function Manual, 12/2018, 6SL3097-5AR00-0BP1
has not yet been performed
Acceptance test
7.3 Acceptance test with Startdrive
345

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents