Control of the safety functions
5.3 Activation via PROFIsafe
Safety status word 1 (S_ZSW1)
S_ZSW1, input signals
see function diagram [2806].
Table 5- 6
Description of safety status word 1 (S_ZSW1)
Byte
Bit
0
0
1
2
3
4
5
6
7
1
0
1
2
3
4
5
6
7
Signals not relevant for Basic Functions: It is not permissible that they are evaluated.
1)
218
Meaning
STO active
SS1 active
SS2 active
SOS active
SLS active
Reserved
SLP active
Internal Event
SLA active
Active SLS level bit 0
Active SLS level bit 1
SOS selected
SDI positive active
SDI negative active
Reserved
SSM (speed below limit value)
1
STO active
0
STO not active
1
SS1 active
0
SS1 not active
0
1)
0
1)
0
1)
0
1)
1
Internal event
0
No internal event
0
1)
0
1)
0
0
1)
0
1)
0
1)
0
1)
Function Manual, 12/2018, 6SL3097-5AR00-0BP1