General Information About Operating Components With Safety Integrated Activated - Siemens SINAMICS S120 Function Manual

Safety integrated
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

General information about SINAMICS Safety Integrated

2.6 General information about operating components with Safety Integrated activated

2.6
General information about operating components with Safety
Integrated activated
It is not permissible to withdraw and insert components. Malfunctions can occur when
components are withdrawn or inserted that are used for Safety Integrated. However, this
does not mean that the fail-safe state is exited. For example, PROFIsafe communication is
not reestablished after this event.
Withdrawing and inserting components used for Safety Integrated (power units, Sensor
Modules, TM54F) during operation and in the deactivated state is not permissible. Activating
the components always requires a POWER ON (see Chapter "Modular machine concept
Safety Integrated (Page 325)").
38
Function Manual, 12/2018, 6SL3097-5AR00-0BP1
Safety Integrated

Hide quick links: