Commissioning
6.11 PROFIsafe communication
Note
Unique PROFIsafe addresses
You must ensure the unique assignment of the PROFIsafe address throughout the network
and the CPU.
• The failsafe I/O of PROFIsafe address type 1 is addressed clearly by its failsafe
destination address.
• The failsafe destination address of the failsafe I/O (drive units in this case) must be
unique for the entire failsafe I/O throughout the network and the CPU (system-wide). The
failsafe I/O of PROFIsafe address type 2, e.g. modules of the ET 200SP type, must also
be taken into account.
• Note also the corresponding documentation in the TIA Portal online help in Section
"SIMATIC Safety - Configuration and programming". (SDR001)