Siemens SINAMICS S120 Function Manual page 39

Safety integrated
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Functions
Advanced
Safely-Limited Position
Functions
Transfer safe
position values
Safe Cam
The use of this safety function without an encoder is permitted only for the following motors:
1)
- Induction motors
- SIMOTICS A-1FU synchronous motors (previously: SIEMOSYN)
- Reluctance motors
The configuration of the Safety Integrated Functions and the selection of monitoring with or
without encoder is realized in the safety screens of the Startdrive commissioning tool.
Safety Integrated
Function Manual, 12/2018, 6SL3097-5AR00-0BP1
General information about SINAMICS Safety Integrated
Abbr. With
With-
Brief description
en-
out
coder
en-
coder
SLP
Yes
No
Safely Limited Position
SP
Yes
Yes
Transfer safe position values
1)
SCA
Yes
No
Safe cam
2.5 Drive monitoring with or without encoder