Siemens SINAMICS S120 Function Manual page 139

Safety integrated
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Transmission via PROFIsafe
Once SLA has been parameterized and selected, the monitoring results are transmitted in
status words S_ZSW1.8 or S_ZSW2.8 (see Chapter "Process data (Page 217)").
Note
Response to bus failure
If p9580 ≠ 0 and SLA is active, in the event of a communication failure, the parameterized
ESR reaction only occurs if a STOP with delayed pulse suppression when the bus fails has
been parameterized as the SLA response (p9579 ≥ 10).
Transfer via SIC
Once SLA has been parameterized and selected, the monitoring results are also transmitted
in SIC in status word S_ZSW1B.8 (Chapter "Safety Info Channel and Safety Control Channel
(Page 251)"). You will find this status word in telegrams 700 and 701.
Function diagrams (see SINAMICS S120/S150 List Manual)
• 2838
Overview of important parameters (see SINAMICS S120/S150 List Manual)
• p9501
• p9576
• p9578
• p9579
• r9714[3]
• r9719.17
• r9720.8
• r9721.11
• r9722.8
• r9789
• r9790
Safety Integrated
Function Manual, 12/2018, 6SL3097-5AR00-0BP1
SLA (Safely-Limited Acceleration)
SI Motion enable safety functions (Control Unit)
SI Motion SLA filter time (CU)
SI Motion SLA acceleration limit (CU)
SI Motion SLA stop response (Control Unit)
CO: SI Motion diagnostics velocity: Actual SLA velocity limit on the Con-
trol Unit
CO/BO: SI Motion control signals 2: Deselect SLA
CO/BO: SI Motion drive-integrated control signals: Deselect SLA
CO/BO: SI Motion status signals (Control Unit): SLA active
CO/BO: SI Motion drive-integrated status signals (Control Unit): SLA ac-
tive
CO: SI Motion SLA acceleration acceleration diagnostics
SI Motion acceleration resolution
Description of Safety Integrated functions
4.2 Safety Integrated Extended Functions
137