7.2.3

Test scope for specific measures

Scope of partial acceptance tests for specific measures
The measures and points specified in the table refer to the information given in Section
Content of the partial acceptance test (Page 338).
Table 7- 1
Scope of partial acceptance tests for specific measures
Measure
A) Documentation
Replacement of
No
the encoder
system
Replacement of
Yes, Points 1 and
an SMC/SME
2
Replacement of
Yes, Points 1 and
a motor with
2
DRIVE-CLiQ
Replacement of
Yes, Points 1 and
the following
2
hardware: Con-
trol Unit, Motor
Module, Power
Module, or Safe
Brake Relay
Replacement of
Yes, Points 1 and
the TM54F
2
Firmware modi-
Yes, only Point 2
fication
(CU /
1)
power unit /
Sensor Mod-
ules)
Change to a
Yes, Points 4 and
single parame-
5.
ter of a safety
function (e.g.
SLS limit)
Transfer of
Yes
project data to
other machines
(series commis-
sioning)
Other firmware
Yes, only Point 2
version
on
1)
Simotion D
Upgrading or downgrading
1)
Safety Integrated
Function Manual, 12/2018, 6SL3097-5AR00-0BP1
B) Functional testing
C) Functional testing
of safety functions
of the forced checking
procedure (test stop)
No
No
No
No
No
No
Yes, Points 1 or 2
Yes, only Point 1
and 3
Yes, but only testing
Yes
of the selection of the
safety functions
Yes, if new safety
Yes
functions are to be
used
Yes, test the appro-
No
priate function
Yes, but only testing
Yes
of the selection of the
safety functions
Yes, if new safety
Yes
functions are to be
used
7.2 Contents and depth of the acceptance test
D) Functional
testing of actual
value acquisition
Yes
Yes
Yes
Yes, only Point 1
Yes, only Point 1
Yes, only Point 1
Yes
Yes
Yes, only Point 1
Acceptance test
E) Conclusion
of the report
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
341