Description of Safety Integrated functions

4.3 Safety Integrated Advanced Functions

4.3
Safety Integrated Advanced Functions
4.3.1

Note regarding PFH values

Note
PFH values
The PFH values of the individual SINAMICS S120 safety components can be found at:
PFH values (https://support.industry.siemens.com/cs/ww/en/view/76254308)
4.3.2

License for Extended Functions or Advanced Functions

● One license is required for each axis that is operated with Safety Integrated Extended or
Advanced Functions. You enter the associated license key with the "License Key" button
in Startdrive. Then activate the license key via "Activate".
As an alternative, you can enter the license key into parameter p9920 in the ASCII code.
The license key is activated using parameter p9921 = 1.
● For information on how to generate the license key for the product "SINAMICS Safety
Integrated Extended Functions" or "SINAMICS Safety Integrated Advanced Functions"
read the section "Licensing" in the SINAMICS S120 Function Manual. An insufficient
license is indicated via the following fault and LED:
– F13000 → licensing not sufficient
– LED RDY → flashes red with 2 Hz
● When purchasing your drive, you can already decide to use Safety Integrated Functions,
and you will then be provided with the required license(s) on the memory card supplied.
In this case, you do not have to explicitly activate the licenses.
● A trial license is available for test purposes; this allows you to use Safety Integrated
functions for a specific time without having a valid license.
Details on the trial license can be found in the "SINAMICS S120 Function Manual Drive
Functions", Chapter "Licensing".
4.3.3

Safely-Limited Position (SLP)

The Safely-Limited Position function (SLP) is used to safely monitor the limits of two
traversing or positioning ranges which can be switched over by a safe signal.