Upgrading R6csi/R7csi/R8csi to Avaya Communication
Manager on an Avaya DEFINITY Server CSI

Check Link Status

1. Enter display communication-interface links and press
all enabled links
2. Type status link number and press
3. Write down which links are in service.

Save Translations

1. Type save translation and press
to the original translation flashcard, which takes about 10 minutes.
When the save translations is successful, the error code must be a zero;
otherwise, the translations are not copied. If the translations were
corrupted, the following error message displays when logging in:
!
WARNING:
Translation corruption detected; call Avaya distributor immediately.
NOTE:
The save translation command cannot function if translations are
corrupt. Refer to
clear the problem.

Save Announcements (if necessary)

NOTE:
The TN750C and TN2501AP Integrated Announcement circuit packs store
announcements in nonvolatile memory; saving the announcements to a
flashcard is optional.
1. If the PPN contains a TN750/B Announcement circuit pack, type display
announcements and press
2. If administered recorded announcements are listed, type save
announcements UUCSS and press
about 30 minutes.
NOTE:
For some DEFINITY ECS software versions, type save
announcements from UUCSS. Type help and press
complete command syntax.
3-14
Issue 7 November 2003
for each enabled link.
Enter
to write all translations from memory
Enter
''Translation Corruption Detected'' on page A-2
.
Enter
. For example, 01D03. This takes
Enter
. Write down
Enter
to
for
Enter
555-233-118