System overview
1.7 System Data
1.7
System Data
1.7
Technical Specifications
Unless explicitly specified otherwise, the following technical specifications are valid for
components of the SINAMICS S120 booksize drive system.
Electrical specifications
Line connection voltage
Line frequency
Electronics power supply
Cable-borne radio interference voltage
Standard
•
with line filter
•
without line filter
•
Overvoltage category
*
If a motor holding brake is used, restricted voltage tolerances may have to be taken into account.
Modules
Line Modules in booksize format
Rated supply voltage
•
Active Line Modules in booksize format
Rated pulse frequency
•
Motor Modules in booksize format
DC link connection voltage
•
Rated pulse frequency
•
Ambient conditions
The Safety-Integrated safety function:
The components must be protected against conducted contamination (e.g. by installing them in a cabinet with degree of
protection IP54B acc. to EN 60529).
Provided that conducted interference can be prevented at the installation site, the degree of protection for the cabinet can
be decreased accordingly.
Degree of protection
Protection class
Permissible ambient and coolant temperature (air) during
operation for line-side components, Line Modules and Motor
Modules
Permissible air intake temperature (temperature in the
cabinet) in operation for DC link components
1-10
3-ph. 380 V to 480 V AC ±10 %
(-15 % < 1 min)
47 – 63 Hz
24 V DC, -15/+20 %*
no cable-borne radio interference
Class A1 acc. to EN 55011 or
Category C2 acc. to EN 61800-3
Limit value classes are not complied with
III acc. to EN 60 664-1
3AC 380 V
8 kHz
510 V DC to 750 V DC
4 kHz
IP20B acc. to EN 60529
I (with protective conductor connection) and
III (PELV) acc. to EN 61 800-5-1
0 °C to 40 °C without derating,
>40 °C to +55 °C (see derating characteristics)
0 °C to +55 °C
Equipment Manual for Booksize Power Units
Equipment Manual, (GH2), 03/2006 Edition, 6SL3097-2AC00-0BP3