AC100 HIGH-PERFORMANCE VC INVERTER MANUAL
control parameter setting and adjustment, please refer to details of F6 parameter groups.
4, When choosing VC mode, all inverters can only drive one motor, and the capacitance rating difference
between the inverters and the motor can't be too large. The inverter can be 2 rating bigger or 1 rating
smaller than the motor. Otherwise, the control performance will descend. Or the drive system can't run
normally.
F0.01
Speed / torque control mode
0: speed control when using speed control, the inverter output command given frequency, and the output torque
and load torque is automatically matched, but the output torque is limited by the maximum output torque (see [F6.11])
limits, and when the load torque is greater than the maximum output torque, the inverter output torque is limited, the
output frequency and the set frequency would not be the same.
1: Torque Control when using torque control, the inverter output command given torque. At this time, the output
frequency and load speed automatic matches, but the output frequency is limited by the torque control forward /
reverse maximum speed (see [F7.08, F7.09]). When the load speed is greater than the set maximum speed limit,
the inverter output frequency is limited and the output torque would not be the same as the set torque; for torque
control specific parameter settings, refer to F7 parameter group.
Note: when the external terminals X1 - X7 input function is selected to "13", the speed and torque would
switch by the turning on and off of external terminal, and terminal operation is better than the function code
[F0.01]. Torque control is only effective when (F0.00 = 0,2,5,7);
F0.02
Run command channel
It is channel for inverter receiving run and stop order and run direction. It is only used for starting and stopping control
under torque control.
0: Keyboard control Inverter run and stop is controlled by keyboard key FWD, REV/JOG, STOP/RESET. REV/JOG
key is defined as reverse when [F4.02] set as "0" and jog when [F4.02] set as "1". Please refer to details of [F4.02].
1: Terminal control Factory default as two line mode 1 control mode. Under two line mode 1, inverter run, stop and
direction is controlled by whether "FWD" or "REV" set for [F2.00-F2.07] "multi function input terminal" connects to
control board terminal (COM) or not. "FWD" and "REV" definition refer to [F2.00-F2.07]. When under other control mode,
run, stop and direction refer to [F2.12].
2: RS485 communication control Inverter run, stop and direction is controlled by the signal received by RS485
communication terminal. Details refer to Fd communication control parameter group and appendix 2: RS485
communication protocol.
3: Optional card Inverter run, stop and direction is controlled by the signal received by optional card input signal. For
the optional card installation, parameter setting and soon, please refer use manual packing with the optional card.
Note: 1. When doing fault reset, key STOP/RESET, control terminal reset order and RS485 communication
terminal are valid reset order.
2. When inverter input frequency is 0Hz or lower than Min output frequency [F1.26]. As long as you input
run order, keyboard FWD indicator will be on, the motor will run as 0 frequency.
Tip: keyboard key STOP/RESET function can be selectable. Under exterior terminal control or communication
control, it can be defined as stop function. Please refer to [F4.03]. Under exterior terminal control, if use
STOP/RESET to stop, inverter stops and close exterior terminal run order. It needs to input exterior
terminal stop order and unlock. The exterior terminal run order will be valid again. So is the
communication control.
Setting range: 0-1
Setting range: 0-3
78
FUNCTION PARAMETER SPECIFICATION
Factory default: 0
Factory default: 0