AC100 HIGH-PERFORMANCE VC INVERTER MANUAL
+24V
PLC
S6
COM
K9
S7
K10
Chart 3-5:AC100 Series Inverter Switch Terminal Connection Function Specification
Main Circuit Terminals
Main circuit terminals array and definition
Arrangement sequence of main circuit terminal with 18.5kW or less power(15 ~ 18.5KW for steel cover machine)
Arrangement sequence of main circuit terminal with 15-22KW(15~22KW for plastic cover machine)
Arrangement sequence of main circuit terminal with 22~30KW (standard machine without PB terminal) (22KW for steel
cover machine)
Arrangement sequence of main circuit terminal with 37~110kW
Short +24V terminal and PLC terminal
PLC terminal receiving external power input, detailed in Drawing 3-22,3-23
Short PLC terminal and COM terminal
Disconnect GND terminal and PE discharge loop
Connect GND terminal and PE discharge loop
(-)
(+)
PB
R
S
26
T
U
V
W
E